The Process of Testing For Valve Leaks On The KM. Kendhaga Nusantara Using A Hydrostatic Pressure Test

Authors

  • Adi Kurniawan Yusim Universitas Diponegoro
  • Muhammad Afif Fadila Universitas Diponegoro
  • Sarwoko Sarwoko Universitas Diponegoro

DOI:

https://doi.org/10.62012/zl.v1i3.11457

Keywords:

Repair, Gate Valve, Hydrostatic Pressure Test.

Abstract

The process of testing the leak on the valve on the important stages of vessels is carried out and regulated by the BiroKlasifikasi Indonesian (BKI) as a Class which refers to the International Association of Classification Societies (IACS).Pipes and fittings shall be tested by hydrostatic pressure not less than 1.5 times the nominal pressure. In this study, the 4gate valves tested had a nominal pressure from the manufacturer of 10 bar, so they had to be tested up to a pressure of 15bar. The valves have been tested one by one with the Hydrostatic Pressure Test method, using the Test Pump. From the test results found a leak in one of the valves, namely in the disc. The ecommendation given by BKI is to repair it by covering the leak using the material recommended rom the gate valve manufacturer using epoxy type iron glue.

Downloads

Download data is not yet available.

References

Grammenos, C. T. 2010. “The Handbook of Maritime Economics 2nd. Ed". Cornwall: Exeter Premedia Services, MPG Books.

Malvino, K. “www.emaritim.com”, 11 Agustus 2017. [Online]. Available: https://www.emaritim.com/2017/08/ledakan-km-kendhaga-nusantara-berasal.html. [Accessed 05 Juny 2020].

Peter Smith, R. W. Zappe, Valve Selection Handbook: Engineering Fundamentals for Selecting the Right Valve Design for Every Industrial Flow Application, Fifth Edition, Elsevier, USA, 2004.

Marine Machinery, Engines & Controls. “www.brighthubengineering.com”, 30 Juni 2009. [Online]. Available: https://www.brighthubengineering.com/marine-engines-machinery/41043-procedure-of-sw-pump-sea-chest-cleaning/. [Accessed 05 July 2020].

Biro Klasifikasi Indonesia. 2016. “Rules for Machinery Volume III”. Jakarta: Biro Klasifikasi Indonesia.

Published

2020-11-30

How to Cite

[1]
A. K. Yusim, M. A. Fadila, and S. Sarwoko, “The Process of Testing For Valve Leaks On The KM. Kendhaga Nusantara Using A Hydrostatic Pressure Test”, zonalaut, vol. 1, no. 3, pp. 78-83, Nov. 2020.

Issue

Section

Offshore Building Technology and Engineering