Placement And Needs Analysis Cathodic Protection System On Offshore Subsea Gas Pipeline From Pemping Island to Tanjung Uncang Batam

Authors

  • Nur Azisah Departemen Teknik Kelautan Fakultas Teknik Universitas Hasanuddin
  • Daeng Paroka Departemen Teknik Kelautan Fakultas Teknik Universitas Hasanuddin
  • Wahyuddin Wahyuddin Departemen Teknik Kelautan Fakultas Teknik Universitas Hasanuddin

DOI:

https://doi.org/10.62012/zl.v1i3.11978

Keywords:

Pipe, Protection, Corrosion, Sacrificial Anode, DNVGL, ISO.

Abstract

Corrosion is a problem that often occurs in submarine pipelines. This is because the metal pipe material is installed in environments that have a high level of corrosivity. Although corrosion cannot be avoided or eliminated, it can be controlled by cathodic protection. One of them is the sacrificial anode method. The aim of this research is to design a corrosion rate control in an underwater pipe along 13.5km, with a diameter of 16 inches for a design life of 45 years. The anode used is a 400 mm long and 40 mm thick anode made of aluminum alloy. In designing this cathodic protection, the writer refers to DNVGL-F103 and ISO 15589-2. From the results of this study, we will get the total anode needed to protect the pipe and the installation distance between the anodes. Based on the total anode, it can be seen the estimated cost needed in making cathodic protection.

Downloads

Download data is not yet available.

References

Bethune, K. And Hartt, “A Novel Approach To Cathodic Protection Design For Marine Pipelines: Part II Applicability Of The Slope Parameter Method”, Presented At Corrosion, Paper No.00674, 2000.

DNV GL-RP F103, Cathodic Protection Of Submarine Pipelines, Det Norke Veritas Industry AS, Hovik, 2016.

ISO 15589-2, “Petroleum, Petrochimical And Natural Gas Industries-Chatodic Protecti0n Of Pipeline Transportation System - Part 2:Offshore Pipelines”, International Organization For Standardization, Washington, DC, 2012.

Jones, D.A., Principles And Prevention Of Corrosion, First Edition, Macmillan Inc., New York, Pg. 437-445,1992.

Kurnia, Dadang, Perancangan Sistem Proteksi Katodik (Cp) Anoda Korban Pada Pipa Baja, Universitas Pamulang : Pamulang, 2016.

Mulyono, Pribadi Ridzky.,Perancangan Sistem Proteksi Anoda Tumbal Pada Pipa Baja Api 5l Grade B Dengan Variasi Jumlah Coating Yang Dipasang Dalam Tanah, Institut Teknologi Sepuluh Nopember : Surabaya, 2017.

Peabody,Control Of Pipeline Corrosion 2nd Edition, 2001.

Sunde, E.D., Earth Conduction Effects In Transaction Systems, Dover Publishing Inc., New York, NY, Pg. 70-73, 1968.

Www.Corrosion-Doctors.Org/Lnhibitors/Lessonl 1 .Htm. Diakses Pada 29 April 2020

Www.Bukalapak.Com. Diakses Pada Tanggal 30 Juni 2020

Published

2020-11-30

How to Cite

[1]
N. Azisah, D. Paroka, and W. Wahyuddin, “Placement And Needs Analysis Cathodic Protection System On Offshore Subsea Gas Pipeline From Pemping Island to Tanjung Uncang Batam”, zonalaut, vol. 1, no. 3, pp. 57-63, Nov. 2020.

Issue

Section

Offshore Building Technology and Engineering

Most read articles by the same author(s)